• Lab Mechanical Stirring Glass Fermenter, 5L Glass Fermenter

    TOPTION brand fermentation tank is widely used in dairy products, beverages, biological engineering, pharmaceutical, fine chemical industry, etc. Its structure is designed with interlining, insulation, heating, cooling, heat preservation. 



  • The main features of this type 5L glass fermenter:

    1. PLC automatic control system – This series fermentation equipment adopts top mechanical stirring system, stirrer’s revolving speed is stepless adjustable, fermentation parameters such as temp. PH, dissolved oxygen, automatic control, automatic recording, storage, printing, suitable for test in fermented products.


    2. This series fermentation tanks are suitable for all kinds of small fermentation experiments in microorganism, it has good stability, convenient operation, etc. 


    3. User can according to the fermentation process to customize corresponding structure and the modelling, multistage fermentation contains seed tand and fermentation tank.



  • The technical parameter of TOPTION laboratory glass fermenter:


    Model

    TPF-GJ Lab Mechanical Stirring Glass Fermenter

    Volume range

    2L

    3L

    5L

    7L

    10L

    Tank material

    Borosilicate glass & 316L stainless steel combination

    Liquid loading coefficient

    70%-80%

    Blade form

    Flat paddle / Inclined paddle / Bend paddle / Arrow paddle (Customize based on your actual request)

    Structure type

    Table, frame structure

    Stirring drive mode

    Speed governing plate control, rotate speed 50rpm/min – 1000rpm/min, range adjustable.

    Sterilization method

    In sterilization

    Standard interface

    PH / DO / Temp. Probe port / Inoculation port / foaming alarm port / acid / supplement, etc

    Control method

    LCD touch screen operation interface, PLC controller, Temperature, Mixing speed, PH value, DO value, vacuuming, multiplexing, acid, alkali, pressure, air volume parameters are measured in real time and automatic control. Digital setting, rapid correction, measurement data display storage and printing, password management, etc. And the communication interface can be connected with the upper machine.

    Fermenter characteristic

    Disinfection, safe and reliable. The method of inoculation is diverse and reliable. Elegant appearance and flexible operation. Easy to remove and install.


  • How to operate this laboratory glass fermenter system:


    1.Preparatory work before fermentation

    1)Check whether the power supply is normal.


    2) Check the system valve, connector and fastening screws whether are tight.


    3) Check the sealing performance of the fermentation tank, breathing filter, pipeline and valve whether are in good condition, whether have leakage. In-tank whether is sealing (should focus on testing when seasons  change) , to ensure that all valves are closed.


    4) Check the voltage and air pressure whether can be supplied normally. Input power is AC220V ± 10%, 50Hz frequency.


    5) PH electrode operating instructions, please check the relevant specifications.


    6) Check the motor whether can run normally.


    2.Sterilization

    1)The first cleaning system after fermentation system finish installed:

    Tank inner cleaning: could remove the flange which is at the top of the tank, operators could use clean cloth to do manual cleaning, after finish should discharge all the waster water out,the use water washing a few times more. If the fermenter long time don’t use or cultivate bacteria is not same with last time, could use 2% NaOH cleaning, after cleaning could do fermentation system sterilization.


    2)Real tank sterilization:

    After finish preparing the culture medium, put it in the tank, remove: motor line and motor, temperature probe line, the air intake pipe,etc, which are connected to the tank parts. Install PH electrode, ORP electrode and DO electrode (screw on protection functional nuts), put the fermentation tank in the high pressure sterilization pot sterilization thoroughly.


    3.Fermentation

    After natural cooling of the complete sterilization fermenter and the culture medium, install the motor, PH electrode cable, DO cable, ORP cable, temperature electrode. Sterile air ventilation (the pressure of glass tank shoule not be larger than 0.05Mpa, the vent valve could keep open), on the operating interface to set the related fermentation process control parameter values.


    4.Process sampling

    By peristaltic pump suction or charge a trace of air with pressure in tank, open the silicone tube clip.


    5.Material discharging

    After the fermentation process, shut off the gas source, power supply, material feeding, the fermentation finished.


    6.Maintenance and repair

    1)The Fermenter should be placed in a clean, dry, well ventilated environment, the water and steam shall not directly splashed ove on the electrical parts.


    2) After you use the fermenter, must be timely cleaning, prevent fermented liquid stem node within the fermentation tank,  pipeline and valve.


    3) All kinds of instruments, should according to the requirement to maintain and storage, pressure gauge, safety valve, temperature instrument should be calibrated once a year.


    4) When to stop using the equipment should be clean and dry. The filter element of filter should be clean, dry and properly kept.


    5) The surrounding environment of air compressor should be kept clean, the air is fresh, the drain for the living water, the fermenter body surface clean.


    7.Matters need attention

    1)When the sterilizing filter sterilization, the pressure shall not exceed 0.13 MPa.


    2)Make sure that the aeration tank air pressure relief to 0.02-0.02 Mpa, must not higher than this pressure value.More fermenter system customize welcome contact [email protected]
     consult more.